Thermal Analysis --> Dilatometers --> L75/SOFTWARE
L75 Standard Software
Standard Software Package TA-WIN and TA-DIL with Data Acquisition and Evaluation

Features:

A) Data acquisition part:
  • Set up of temperature controller with heat up speed, dwell time and cooldown speed.
  • Up to 16 different stages can be programmed
  • Up to 99 cycles can be programmed
  • Different measuring systems for single and dual push rod can be selected
  • Essential measurement data for documentation have to be entered:
      Sample name, correction sample name, operator, laboratory, atmosphere, gas flow, sample material, commentary, sample length, selected measuring range, max. temperature, deration of run, sampling frequency.
  • The scheduler for automatic measurement sequences, for up to 16 preprogrammed
        runs can be programmed.


B) Data evaluation part:
  • real time color display
  • automatic and manual scaling
  • time vs. Temperature profils, or time vs. Delta L selection
  • first and second order derivatives
  • analysis save feature
  • foreground/background operation
  • multitasking operation for operation of different instruments or tasks
  • zoom / individual segment display
  • multiple curve / module overlay
  • on-line help menu
  • annotation and drawing tools
  • copy to clip board function
  • post collection editing
  • ASCII export
  • data smoothing
  • baseline file subtraction
  • cursor function
  • statistical curve evaluation (mean curve)
  • print out of table of data and coefficients
  • calculation of Delta L, CTE, relative expansion Delta L / L0
  • curve arythmetic
  • softening point evaluation standard feature
Special Dilatometer Software

  • L75/DTA
        DTA measurement software for Dilatometers

  •     L75_SDD_ENG.pdf    Size 290 KB

  • L75/SDC
        Simultaneous Dilatometer Calorimeter Measurement
        L75_SDC_ENG.pdf    Size: 17 KB


  • L75/RCS
        Rate Controlled Sintering Software

  •     L75_RCS_ENG.pdf    Size: 104 KB

  • L75/SOFT
        Softening Point Software

  •     L75_SPD_ENG.pdf    Size: 16 KB

    All LINSEIS Thermal Analysis Instruments are controlled through sophisticated Windows® software. The complete program consists of three sections: temperature control, data acquisition, and data evaluation. Essential sample information is entered in the data acquisition section.
    Data Acquisition section

    Screenshot Softwar L75

    Essential data for each sample test includes; operator, laboratory, atmosphere, gas flow, material, sample file name, zero file name, comments, sample length, measuring range, max. temperature, duration of run, sampling frequency, heating and cooling rates, number of cycles.

    All menus are easily understood and intuitive. The software is quickly mastered with minimal training needed.

    L75_Software Screenshot

    Evaluation section



    The evaluation is part of the complete windows software, It features a number of functions enabling a full evaluation of all types of data. All evaluation and data collection can be performed simultaneously. Data can be corrected using zero and calibration correction. Data evaluations include: absolute length change, relative length change, and coefficient of thermal expansion. A mean curve with statistical analysis can be performed on multiple curves. Graphical displays can be printed on all windows compatible printers or plotters. Data can be displayed and printed in a table format. The software also includes an ASCII export feature.
    Download